SSV Sampling Valves plastomer-lined or fully stainless steel
for safe and representative sampling of corrosive or toxic process media from pipelines and vessels, without process interruptions.

Main Features
• Full-port design, conf. to TA-Luft
• Safe and simple operation by handwheel
• spring to close (deadman lever optional)
• Precision sampling for small sample
• volumes by simple stroke adjustment
• Only one opening to the atmosphere
• All-purpose valve unit - installation on
• large size pipelines, vessels etc.
Options
• Bodies with heating jacket
• Needle adapter for bottle with septum
• Safety cabinet with inspection windows
• Flange versions: groove, PN40, ANSI 300lbs etc.
• Vertical adapter, sealing plug, carbon filter
• Metal safety basket
• Bottle support, height-adjustable
• Pneum. quarter turn actuator, single-acting FC
Technical Data
• Nom. Sizes: DN15 - DN150 resp. ½" - 6"
• Flanges according to DIN PN10/16 resp.
• ANSI 150lbs
• Face to face acc. to EN 558-1 range 1
• resp. range 3 and ASME B16.10
• Bodies: stainless steel casting CF-8M
• Linings: PFA, PFA-AS (anti-static)
• Sealing Cone: FFPM (Perfluor)
• Valve seat: PTFE-T |
Operating Conditions (dep. on material selection)
• Pressure: up to 16 bar (232 psi)
• Temperature: -20°C (-4°F) up to +160°C (+320°F) |
SSV-B Sampling Ball Valves plastomer-lined or fully stainless steel
for the extraction of a defined sampling volume out of pipelines or vessels - safe and reliable, without any process interruptions

Main Features
• Full-port design, no pressure drop
• Safe and simple operation by handlever
• or pneum. quarter turn actuator
• Defined sampling of approx. 45 ml/op.
• by PFA-lined ball, one-piece shaft/ball
• Only one opening to the atmosphere
• All-purpose valve unit - installation on
• large size pipelines, vessels etc.
Options
• Bodies with heating jacket
• Flange versions: groove, PN40, ANSI 300lbs etc.
• Metal safety basket
• Bottle support, height-adjustable
Technical Data
• Nom. Sizes: DN15 - DN150 resp. ½" - 6"
• Flanges according to DIN PN10/16 resp.
• ANSI 150lbs
• Face to face acc. to EN 558-1 range 1
• resp. range 3 and ASME B16.10
• Bodies: stainless steel casting CF-8M
• Body linings: PFA, PFA-AS (anti-static)
• Liner/ball: PTFE/Duplex PFA-encaps.
• Ball seat: PTFE-T
Operating Conditions (dep. on material selection)
• Pressure: up to 16 bar (232 psi)
• Temperature: -40°C (-40°F) up to +200°C (+392°F)
Technical Data Function
SIV Sampling Valves plastomer-lined or fully stainless steel
for safe and representative sampling of corrosive, aggressive or even toxic process media from pipelines, without process interruptions.

Main Features
• Dead-space-free design, conf. to TA-Luft
• Safe and simple operation by handwheel
• or deadman lever (spring to close)
• Precision sampling for small sample
• volumes by spindle stroke adjustment
• Maintenance-free stuffing box or bellows
• seal, replaceable spindle gasket
Options
• Bodies with heating jacket
• Needle adapter for bottle with septum
• Safety cabinet with inspection windows
• Handwheel spring to close
• Flange versions: groove, PN40, ANSI 300lbs etc.
• Vertical adapter, sealing plug, carbon filter
• Metal safety basket
• Pneum. linear stroke actuator, single-acting FC
Technical Data
• Nom. Sizes: DN15 - DN150 resp. ½" - 6"
• Flanges according to DIN PN10/16 resp.
• ANSI 150lbs
• Face to face acc. to EN 558-1 range 1
• resp. range 3 and ASME B16.10
• Bodies: stainless steel casting CF-8M or
• CF-3M
• Linings: PFA, PFA-AS (anti-static), PVDF
• Spindle gasket: Valflon®
Operating Conditions (dep. on material selection)
• Pressure: 1 mbar (0.014 psi) up to 40 bar (580 psi)
• Temperature: -40°C (-40°F) up to +230°C (+446°F)
Technical Data
SRS Reactor Sampling Systems plastomer-lined, manually
for safe, representative and enclosed sampling of aggressive or toxic process media out of reactors and tanks, without process interruptions.

Main Features
• Robust, compact construction, easy
• and safe operation
• Simple extension with additional compo-
• nents resp. upgrading of existing systems
• on site
• Main valve standard 1"-150lbs, PFA-lined,
• manually operated
• Two-hole mounting plates for easy
• installation of additional connections
• Ball seat made of Perfluor, for wear-free
• and reliable sealing of the PTFE hollow ball
• Conforming to FDA regulations
Modular Design
Reactor Sampling Systems are available as basic versions such as SRS-P (PFA-lined) resp. SRS-P-P, PFA-lined with air driven diaphragm pump.
The systems operate, i.e. extract the re-quired sample by means of vacuum or under pressurized conditions. In addition to the basic units, a large variety of accessories and options can be selected and the system will be assembled easily and complete, just according to the given specification.
Operating Conditions (dep. on material selection)
• Press.: 500 mbar (7.25 psi) up to 10 bar (145 psi)
• Temperature: -40°C (-40°F) up to +180°C (+356°F)
Technical Data
|